Brand Name : | Green Spring |
Model Number : | LSY-30019 |
Certification : | ISO13485,ISO9001 |
Price : | Negotiable |
Payment Terms : | T/T |
Supply Ability : | 100000 tests per day |
Delivery Time : | 7~14days |
Porcine Streptococcus Suis(S.suis) Ab ELISA Test Kit 192 Wells/Kit
1. Brief
The GreenSpring® Porcine Streptococcus suis antibody ELISA kit is
used to detect Porcine Streptococcus suis antibodies in porcine
serum and assess the immunity conditions against S.suis in the pig
farms and investigation epidemiology of the S.suis.
2. Principle
The GreenSpring® Porcine S.suis antibody ELISA test kit is made
from the antigen coated microtiter plate(coated with S.suis
antigen) and other reagents. It applies the Solid-phase ELISA
principle to test the antibodies against S.suis in porcine serum.
In the test, the coated antigen combine with S.suis-Ab in serum,
then add enzyme conjugate to specifically bind with complex of
coated antigen+S.suis-Ab+enzyme conjugate on the microplate. With
the TMB substrate, it will generate an amount of color. The depth
of color is relative with the content of the S.suis-Ab, when the
value of color is greater than the cut-off value, the pigs are
vaccinated well or natural infected exist.
3. Components
1 | S.suis antigen coated microplate | 96T X 2 | |
2 | Enzyme conjugate | 22ml | yellow lid |
3 | Sample diluent solution | 50ml | transparent lid |
4 | S.suisNegativecontrol serum | 1.5ml | green lid |
5 | S.suisPositivecontrol serum | 1.5ml | red lid |
6 | Substrate | 12ml X2 | orange lid |
7 | Stop solution | 12ml | blue lid |
8 | 20×concentrated washing buffer | 50ml | white lid |
9 | Adhesive Foil | 2 pieces | |
10 | Instruction | 1 piece |
4. Material Required But not Provided
1) Microplate Reader (double-wave length: 450/630 nm).
2) Precise micropipette (single-channel
1-100ul,0.5-10ul,multi-channel 30-300ul)
3) Constant temperature box or water bath box.
4) Oscillator.
5) Microplate Washer.
6) Disposable tips (10ul, 200ul)
7) Deionized water
5. Sample requirement
1) The samples are porcine serum, which should be collected with no
bacteria. The storage time should be less than 1 week at 2-8 ℃, if
for long term, it should be kept at -20℃.
2) Avoid to use the samples with severe hemolysis, precipitate,
contaminated by bacteria or protein suspension.
3) The EDTA, heparin sodiun and other anticoagulants will not
affect the results.
6. Preparation
1) Bring ELISA reagents to the room temperature (20-25 ℃) for 30
min to get best results.
2) Sample dilute: Dilute sample with the sample diluent solution at
40 times. The diluted sample need to mix evenly to get better
results.
3) Washing solution preparation: Dilute the 20×concentrated washing
buffer with deionized water at 20 times.
7. Procedure
1) Take out the coated plates(Can be detached) and record the
sample position on a worksheet. Set 2 wells for negative control
serum, add undiluted negative control serum, 2 wells for positive
control serum, add undiluted positive control serum, 100μL/well(It
is OK not to set blank control). Others are sample wells, add the
diluted sample, 100μL/well(both single- well and double-well test
is OK).
2) Mix gently, incubate at 37℃ for 30 min.
3) Remove adhesive foil. Pour the liquid out of the wells, add the
diluted Washing buffer into each well fully, be static for 10s,
directly pour out. Repeat 3 times, at last time pat to dry on
absorbent paper.
4) Add 100μL enzyme conjugate into each well.
5) Cover plate with new adhesive foil. Incubate at 37℃ for 30 min.
6) Repeat step 3(washing).
7) Add substrate into each well, 100ul/well, mix properly, incubate
for 10 min at 37℃ in the dark with new adhesive foil.
8) Add stop solution into each well, 50ul/well, mix gently and
determine the result.
9) Measure the OD value of each well with a photometer at dual-wave
length 450nm/630nm.
8. ELISA analysis
For the assay to be valid, the positive control wells’ average OD
value must be greater than or equal to 0.6, and the negative
control wells’ average OD value is less than 0.15. Otherwise the
test is invalid, need test again.
The result is judged by S/P value,
S/P=(Sample OD450/630- NCx(—))/( PCx(—)- NCx(—)), NCx(—) means
Negative control’s average OD450/630 value, PCx(—) means Positive
control’s average OD450/630 value
If S/P≥0.2, it is positive; less than 0.2, it is negative.
9. Precautions and warnings for users
1. This test kit is for research use only.
2. Do not use reagents expired, do not mix reagents from different
lots.
3. Read the Manual carefully before use.
4. Experiment rubbish should be dealt with high pressure steam
sterilization at 121 ℃ for 30 minutes, or treated with 5.0g/L
sodium hypochlorite disinfectant for 30 minutes, then discard.
5. MicroWell plate removed from the refrigerated environment should
be balanced moisture to dry at room temperature, then can be
opened. Put back unused MicroWell plate into dry foil bag and
sealed at 4 ℃. Unused liquid reagent should cover caps, store at
2-8 ℃ in dark with other group components.
6. If the 20×concentrated washing buffer appears crystal, it is
normal, put at 37℃until been dissolved.
7. Should use Micropipettor to add sample and reagents, and often
proof its accuracy.
8. When adding washing buffer, should be full but no overflow,
avoid appearing free enzyme at mouth of well or cross pollution
between wells.
9. Stop solution is corrosive, use large amount of water to wash
immediately when touch the skin or clothes.
Specifications:96 wells×2.
Expiry date:12 months.
Storage:Store at 2~8℃, in the dark.
Production Date:On outer-packing of the test kit.
Q1: How long will it take for you to ship?
A1: Usually ships within 7 working days.
Q2: Do you support OEM/ODM?
A2: can be supported. We can customize according to your specific
needs and specific quantities.
Q3: How is your factory doing in terms of quality control?
A3: We have ISO9001 certification and ISO13485 certification, so
far all the production process, we have standard rules, we comply
with the relevant behavior and laws of the government.
Q4: Is after-sales service guaranteed?
A4: We provide professional online technical after-sales service.
If the product fails during the experiment, we can provide
one-to-one guidance through telephone, video and other forms.
Q5: What is your minimum order quantity?
A5: 1Kit.
Q6: What is the shipping method?
A6: Usually by air, we will choose the best shipping method for
you, and we can also ship according to the shipping method you
require.
![]() |