Sign In | Join Free | My burrillandco.com
Home > Porcine Test Kit >

Porcine Streptococcus Suis S.Suis Porcine Test Kit Ab ELISA Kit 192 Wells/Kit

Shenzhen Wensidun Technology Co., Ltd.
Contact Now
    Buy cheap Porcine Streptococcus Suis S.Suis Porcine Test Kit Ab ELISA Kit 192 Wells/Kit from wholesalers
     
    Buy cheap Porcine Streptococcus Suis S.Suis Porcine Test Kit Ab ELISA Kit 192 Wells/Kit from wholesalers
    • Buy cheap Porcine Streptococcus Suis S.Suis Porcine Test Kit Ab ELISA Kit 192 Wells/Kit from wholesalers
    • Buy cheap Porcine Streptococcus Suis S.Suis Porcine Test Kit Ab ELISA Kit 192 Wells/Kit from wholesalers

    Porcine Streptococcus Suis S.Suis Porcine Test Kit Ab ELISA Kit 192 Wells/Kit

    Ask Lasest Price
    Brand Name : Green Spring
    Model Number : LSY-30019
    Certification : ISO13485,ISO9001
    Price : Negotiable
    Payment Terms : T/T
    Supply Ability : 100000 tests per day
    Delivery Time : 7~14days
    • Product Details
    • Company Profile

    Porcine Streptococcus Suis S.Suis Porcine Test Kit Ab ELISA Kit 192 Wells/Kit

    Porcine Streptococcus Suis(S.suis) Ab ELISA Test Kit 192 Wells/Kit


    1. Brief


    The GreenSpring® Porcine Streptococcus suis antibody ELISA kit is used to detect Porcine Streptococcus suis antibodies in porcine serum and assess the immunity conditions against S.suis in the pig farms and investigation epidemiology of the S.suis.


    2. Principle


    The GreenSpring® Porcine S.suis antibody ELISA test kit is made from the antigen coated microtiter plate(coated with S.suis antigen) and other reagents. It applies the Solid-phase ELISA principle to test the antibodies against S.suis in porcine serum. In the test, the coated antigen combine with S.suis-Ab in serum, then add enzyme conjugate to specifically bind with complex of coated antigen+S.suis-Ab+enzyme conjugate on the microplate. With the TMB substrate, it will generate an amount of color. The depth of color is relative with the content of the S.suis-Ab, when the value of color is greater than the cut-off value, the pigs are vaccinated well or natural infected exist.


    3. Components


    1S.suis antigen coated microplate96T X 2
    2Enzyme conjugate22mlyellow lid
    3Sample diluent solution50mltransparent lid
    4S.suisNegativecontrol serum1.5mlgreen lid
    5S.suisPositivecontrol serum1.5mlred lid
    6Substrate12ml X2orange lid
    7Stop solution12mlblue lid
    820×concentrated washing buffer50mlwhite lid
    9Adhesive Foil2 pieces
    10Instruction1 piece

    4. Material Required But not Provided


    1) Microplate Reader (double-wave length: 450/630 nm).
    2) Precise micropipette (single-channel 1-100ul,0.5-10ul,multi-channel 30-300ul)
    3) Constant temperature box or water bath box.
    4) Oscillator.
    5) Microplate Washer.
    6) Disposable tips (10ul, 200ul)
    7) Deionized water


    5. Sample requirement


    1) The samples are porcine serum, which should be collected with no bacteria. The storage time should be less than 1 week at 2-8 ℃, if for long term, it should be kept at -20℃.
    2) Avoid to use the samples with severe hemolysis, precipitate, contaminated by bacteria or protein suspension.
    3) The EDTA, heparin sodiun and other anticoagulants will not affect the results.


    6. Preparation


    1) Bring ELISA reagents to the room temperature (20-25 ℃) for 30 min to get best results.
    2) Sample dilute: Dilute sample with the sample diluent solution at 40 times. The diluted sample need to mix evenly to get better results.
    3) Washing solution preparation: Dilute the 20×concentrated washing buffer with deionized water at 20 times.


    7. Procedure


    1) Take out the coated plates(Can be detached) and record the sample position on a worksheet. Set 2 wells for negative control serum, add undiluted negative control serum, 2 wells for positive control serum, add undiluted positive control serum, 100μL/well(It is OK not to set blank control). Others are sample wells, add the diluted sample, 100μL/well(both single- well and double-well test is OK).
    2) Mix gently, incubate at 37℃ for 30 min.
    3) Remove adhesive foil. Pour the liquid out of the wells, add the diluted Washing buffer into each well fully, be static for 10s, directly pour out. Repeat 3 times, at last time pat to dry on absorbent paper.
    4) Add 100μL enzyme conjugate into each well.
    5) Cover plate with new adhesive foil. Incubate at 37℃ for 30 min.
    6) Repeat step 3(washing).
    7) Add substrate into each well, 100ul/well, mix properly, incubate for 10 min at 37℃ in the dark with new adhesive foil.
    8) Add stop solution into each well, 50ul/well, mix gently and determine the result.
    9) Measure the OD value of each well with a photometer at dual-wave length 450nm/630nm.


    8. ELISA analysis


    For the assay to be valid, the positive control wells’ average OD value must be greater than or equal to 0.6, and the negative control wells’ average OD value is less than 0.15. Otherwise the test is invalid, need test again.
    The result is judged by S/P value,
    S/P=(Sample OD450/630- NCx(—))/( PCx(—)- NCx(—)), NCx(—) means Negative control’s average OD450/630 value, PCx(—) means Positive control’s average OD450/630 value
    If S/P≥0.2, it is positive; less than 0.2, it is negative.


    9. Precautions and warnings for users


    1. This test kit is for research use only.
    2. Do not use reagents expired, do not mix reagents from different lots.
    3. Read the Manual carefully before use.
    4. Experiment rubbish should be dealt with high pressure steam sterilization at 121 ℃ for 30 minutes, or treated with 5.0g/L sodium hypochlorite disinfectant for 30 minutes, then discard.
    5. MicroWell plate removed from the refrigerated environment should be balanced moisture to dry at room temperature, then can be opened. Put back unused MicroWell plate into dry foil bag and sealed at 4 ℃. Unused liquid reagent should cover caps, store at 2-8 ℃ in dark with other group components.
    6. If the 20×concentrated washing buffer appears crystal, it is normal, put at 37℃until been dissolved.
    7. Should use Micropipettor to add sample and reagents, and often proof its accuracy.
    8. When adding washing buffer, should be full but no overflow, avoid appearing free enzyme at mouth of well or cross pollution between wells.
    9. Stop solution is corrosive, use large amount of water to wash immediately when touch the skin or clothes.


    Specifications:96 wells×2.
    Expiry date:12 months.
    Storage:Store at 2~8℃, in the dark.
    Production Date:On outer-packing of the test kit.


    Porcine Streptococcus Suis S.Suis Porcine Test Kit Ab ELISA Kit 192 Wells/Kit


    Q1: How long will it take for you to ship?
    A1: Usually ships within 7 working days.


    Q2: Do you support OEM/ODM?
    A2: can be supported. We can customize according to your specific needs and specific quantities.


    Q3: How is your factory doing in terms of quality control?
    A3: We have ISO9001 certification and ISO13485 certification, so far all the production process, we have standard rules, we comply with the relevant behavior and laws of the government.


    Q4: Is after-sales service guaranteed?
    A4: We provide professional online technical after-sales service. If the product fails during the experiment, we can provide
    one-to-one guidance through telephone, video and other forms.


    Q5: What is your minimum order quantity?
    A5: 1Kit.


    Q6: What is the shipping method?
    A6: Usually by air, we will choose the best shipping method for you, and we can also ship according to the shipping method you require.

    Quality Porcine Streptococcus Suis S.Suis Porcine Test Kit Ab ELISA Kit 192 Wells/Kit for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Shenzhen Wensidun Technology Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)