Porcine Reproductive and Respiratory Syndrome Virus (PRRSV) Antibody ELISA Kit 192 Wells/Kit
1. Brief
The GreenSpring® Porcine reproductive and respiratory syndrome
virusantibody test kit (PRRSV Ab) is used for the detection of
PRRSV antibodies in swine serum; assessment of immunity conditions
against porcine reproductive and respiratory syndrome virus in the
pig farms;andinvestigation epidemiology of the PRRSV.
2. Principle
The GreenSpring® PRRSV antibody ELISA test kit uses the principle
of solid-phase enzyme-linked immunosorbent assay (ELISA), and
consists of a microwell reaction plate coated with high-purityPRRSV
antigen, anti-pig IgG labeled with horseradish peroxidase, and
other reagents. The reaction mechanism is that the coated antigen
is combined with the PRRSV-Ab in the sample, and then combined with
the enzyme-labeled anti-pig IgG antibody to form a "coated
antigen+PRRSV-Ab+enzyme-labeled anti-pig IgG antibody" complex.Add
adding Substrate,Catalytic reaction color development. The color
depth is directly proportional to the amount of PRRSV-Ab. When the
color reaction of the sample is detected, the result obtained by
the microplate reader exceeds the set threshold, and the result is
positive, which indicates that the immune has produced antibodies
or there is a natural infection.
3. Components
1 | PRRSV antigencoated microplate | 96T X 2 | |
2 | Enzyme conjugate | 22ml | yellow lid |
3 | Sample diluent solution | 50ml | transparent lid |
4 | PRRSV-IgG Negativecontrol serum | 1.5ml | green lid |
5 | PRRSV-IgG Positivecontrol serum | 1.5ml | red lid |
6 | Substrate | 12ml X2 | orange lid |
7 | Stop solution | 12ml | blue lid |
8 | 10×concentrated washing buffer | 50ml | white lid |
9 | Adhesive Foil | 2 pieces | |
10 | Instruction | 1 piece |
4. Material Required not Provided
1. Microplate Reader (Dual-wave length: 450/630 nm).
2. Microplate Washer.
3. Micropipettes, adjustable (Single-wave length
1-100ul,0.5-10ul,multi-wave length 30-300ul).
4. Constant temperature box orwater bath box.
5. Oscillator.
6. Disposable tips (10ul, 200ul)
7. Deionized water
5. Sample requirement
1. The samples are porcine serum, which should be collected with
nobacteria. The storage time should be less than 1 week at 2-8℃, if
for long term, it should be kept at -20℃.
2. Avoid to use the samples with severe hemolysis, precipitate,
contaminated by bacteria or protein suspension.
6. Preparation
1) BringELISA reagents to the room temperature (20-25℃) for 30 min
to get best results.
2) Sample dilute: Dilute sample with thesample diluent solution at
40 times(for example: 5ul serum sample+195ulSample diluent
solution), the diluted sample need to mix evenly to get better
results.
3) Washing solution preparation: Dilute the10×concentrated washing
buffer with deionized water at10 times.(eg.10ml 10×concentrated
washing buffer + 90mldeionized water ), if there is crystallization
in the 10×concentrated washing buffer, it is normal, dissolve it at
37℃.
7. Procedure
1. Adding sample: Take out the required coated plates according to
sample quantity (Can be detached) and record the sample position on
a worksheet. Set 2 wells for negative control serum and 2 wells for
positive control serum, add undiluted negative and positive control
serum to its well accordingly, 100 μL/well.Others are wells for
samples, add 100μL/well of the dilutedSample.
2. Cover plate with adhesive foil, incubate at 37℃ for 30 min.
3. Remove adhesive foil.Pour the liquid out of the wells,
addWashing solution into each well fully, be static for about
10s,pour out directly.Repeat3 times, at last time pat to dry on
absorbent paper.
4. Add 100 μL enzyme conjugate into each well.
5. Cover plate with new adhesive foil.Incubate at 37 ℃ for30 min.
6. Repeat step3(washing).
7. Add 100ul substrate into each well, mix properly,incubate for 10
min at 37 ℃ in the dark.
8. Add 50μL stop solution into each well,mix gently for 10sand
determine the result.
9. Measure theOD value with a photometer at 450nm/630nm.
8. ELISA analysis
Measure the OD Value of each well, for the assay to be valid the
following specifications must be met. Theaverage OD value
ofPRRSV-Positive control must be equal to or greater than 0.60,
theaverage OD value ofPRRSV-Negative control must be less than
0.15.
The result is judged by S/P value,
S/P=(Sample OD450/630-NCx(—))/( PCx(—)- NCx(—)),NCx(—) means
Negative control’s average OD450/630value,PCx(—) means Positive
control’s average OD450/630value
If S/P≥0.2, it is positive; less than 0.2, it is negative.
9. Precautions and warnings for users
1. Read the Manual carefully before use.
2. Do not use reagents expired, do not mix reagents from different
lots.
3. Experiment rubbish should bedealt with high pressure steam
sterilization at121℃ for 30 minutes, or treated with 5.0g/L sodium
hypochlorite disinfectant for 30 minutes, then discard.
4.MicroWell plate removed from the refrigerated environment should
be balanced moisture to dry at room temperature, then can be
opened. Put backunused MicroWell plateintodry foil
bagandsealedat4℃.Unused liquid reagent should cover caps,store at
2-8℃ in dark with other group components.
5. Should useMicropipettor to add sample and reagents, and often
proof its accuracy.
6. When adding washing buffer, should be full but no overflow,
avoid appearing free enzyme at mouth of well or cross pollution
between wells.
7. Stop solution is corrosive, use large amount of water to wash
immediately when touch the skin or clothes.
Specification
Packing: 96 wells×2.
Expiry date:12 months.
Storage: Storing at 2~8 ℃in the dark, not freeze.
Q1: How long will it take for you to ship?
A1: Usually ships within 7 working days.
Q2: Do you support OEM/ODM?
A2: can be supported. We can customize according to your specific
needs and specific quantities.
Q3: How is your factory doing in terms of quality control?
A3: We have ISO9001 certification and ISO13485 certification, so
far all the production process, we have standard rules, we comply
with the relevant behavior and laws of the government.
Q4: Is after-sales service guaranteed?
A4: We provide professional online technical after-sales service.
If the product fails during the experiment, we can provide
one-to-one guidance through telephone, video and other forms.
Q5: What is your minimum order quantity?
A5: 1Kit.
Q6: What is the shipping method?
A6: Usually by air, we will choose the best shipping method for
you, and we can also ship according to the shipping method you
require.
![]() |